INSPECTION
PROCEDURE
1. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (DOOR CONTROL SWITCH
ASSEMBLY) (for Regular Cab)
(a) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection
|
Switch Condition
|
Specified Condition
|
1 (L) - 7 (E)
|
Lock
|
Below 1 Ω
|
1 (L) - 7 (E)
|
OFF
|
10 kΩ or higher
|
9 (UL) - 7 (E)
|
9 (UL) - 7 (E)
|
Unlock
|
Below 1 Ω
|
If the result is not as specified, replace the power window regulator
master switch assembly (door control switch assembly).
Text in Illustration
*a
|
Component without harness connected
(Power Window Regulator Master Switch Assembly (Door Control
Switch Assembly))
|
*b
|
Unlock
|
*c
|
Lock
|
|
|
2. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (DOOR CONTROL SWITCH
ASSEMBLY) (for Double Cab, for Crew Max)
(a) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection
|
Switch Condition
|
Specified Condition
|
2 (L) - 1 (E)
|
Lock
|
Below 1 Ω
|
2 (L) - 1 (E)
|
OFF
|
10 kΩ or higher
|
9 (UL) - 1 (E)
|
9 (UL) - 1 (E)
|
Unlock
|
Below 1 Ω
|
If the result is not as specified, replace the power window regulator
master switch assembly (door control switch assembly).
Text in Illustration
*a
|
Component without harness connected
(Power Window Regulator Master Switch Assembly (Door Control
Switch Assembly))
|
*b
|
Unlock
|
*c
|
Lock
|
|
|
|