INSTALLATION PROCEDURE 1. INSTALL CANISTER PUMP MODULE
2. INSTALL CHARCOAL CANISTER ASSEMBLY (a) Install the charcoal canister assembly with the 4 bolts. Torque: 29 N·m {296 kgf·cm, 21 ft·lbf} (b) Attach the wire harness clamp. (c) Connect the vent line hose. (1) Push the vent line hose into the port and push the retainer to lock it. Text in Illustration
NOTICE:
(d) Connect the air inlet line hose. NOTICE:
(e) Connect the purge line hose and slide the clamp to secure the hose. (f) Connect the canister pump module connector. (g) Connect the wiring harness clamp bracket with the nut. Torque: 10 N·m {102 kgf·cm, 7 ft·lbf} |
Toyota Tundra Service Manual > Sfi System: Problem Symptoms Table
PROBLEM SYMPTOMS TABLE Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected areas ...