INSPECTION PROCEDURE 1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT ![]() HINT: The valve opening temperature is stamped on the water inlet with thermostat.
(b) Check the valve opening temperature. Standard valve opening temperature: 80 to 84°C (176 to 183°F) If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.
(d) Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)). If it is not fully closed, replace the water inlet sub-assembly with thermostat. |
Toyota Tundra Service Manual > Sfi System: ECM / PCM Internal Engine Off Timer Performance (P2610)
DTC SUMMARY DTC No. Monitoring Item Malfunction Detection Condition Trouble Area Detection Timing Detection Logic P2610 Soak timer (built into ECM) ECM internal malfunction (2 trip detection logic) ECM Engine running 2 trip DESCRIPTION The soak timer operates after the ignition switch is turned off. ...