INSPECTION PROCEDURE 1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT ![]() HINT: The valve opening temperature is stamped on the water inlet with thermostat.
(b) Check the valve opening temperature. Standard valve opening temperature: 80 to 84°C (176 to 183°F) If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.
(d) Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)). If it is not fully closed, replace the water inlet sub-assembly with thermostat. |
Toyota Tundra Service Manual > Parking Brake: Parking Brake Switch
On-vehicle InspectionON-VEHICLE INSPECTION PROCEDURE 1. REMOVE PARKING BRAKE SWITCH ASSEMBLY 2. CHECK PARKING BRAKE SWITCH ASSEMBLY (a) Measure the resistance according to the value(s) in the table below. Standard resistance: Tester Connection Switch Condition Specified Condition 1 - Switch body gr ...